1 0mm mini t metacarpal plates

Unstable metacarpal and phalangeal fractures

BACKGROUND Accurate open reduction and internal fixation for metacarpal and phalangeal fractures of the hand is required in less than 5% of the patients; otherwise, closed treatment techniques offer satisfactory results in most of these cases as these fractures are stable either before or after closed reduction. AO mini-fragment screws and plates, when used in properly selected cases, can

(PDF) Treatment of phalangeal and metacarpal fractures:A

Plates and screws, 8,9 intramedullary nails, 10,11 external fixation, 12 and Kirschner wires 13 or screws alone 14 have all been described with mixed results. 2,3,15 It has been noted that plates 42 Treatment of phalangeal and metacarpal fractures:A 1.0mm diameter screws or pull-out wires protected mini-condylar plate, dorsal mini-condylar plate, lateral plate Metacarpal head fractures are usually intra-articular

A comparative mechanical analysis of plate fixation in a

Nov 01, 1996 · A Comparative Mechanical Analysis of Plate Fixation in a Proximal Phalangeal Fracture Model Robert E. Lins, MD, Atlanta, GA, Barry S. Myers, MD, PhD, Robert J. Spinner, MD, L. Scott Levin, MD, Durham, NC A biomechanical study compared the mechanical properties of hand and craniofacial plating systems commonly used in proximal phalangeal fractures. Biomechanical Analysis of the Efficacy of Locking Plates Purpose. To analyse the biomechanical characteristics of locking plates under cyclic loading compared to a nonlocking plate in a diaphyseal metacarpal fracture. Methods. Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. An anatomical reduction and stabilization with a nonlocking and a comparable locking plate in mono- or bicortical

Complications of Low-Profile Plate Fixation in Metacarpal

Oct 01, 2020 · Metacarpal fractures are common injuries, and fixation of metacarpal fractures with traditional plate and screw constructs has resulted in complication rates ranging from Complications of Low-Profile Plate Fixation in Metacarpal Oct 01, 2020 · Metacarpal fractures are common injuries, and fixation of metacarpal fractures with traditional plate and screw constructs has resulted in complication rates ranging from

Hand & Wrist Acumed

As part of our mission to help improve overall patient outcomes, Acumed has developed multiple leading-edge product solutions to address fracture fixation, osteotomies, and joint fusions of the hand and wrist. From plates and screws to external fixation devices, our device systems offer multiple opt Hand & Wrist AcumedAs part of our mission to help improve overall patient outcomes, Acumed has developed multiple leading-edge product solutions to address fracture fixation, osteotomies, and joint fusions of the hand and wrist. From plates and screws to external fixation devices, our device systems offer multiple opt

Hand Metacarpals - AO Foundation

We help you diagnose your Hand Metacarpals case and provide detailed descriptions of how to manage this and hundreds of other pathologies Hand Plates - TriMed Expose the metacarpal or phalanx with standard techniques. Plates 1.5 Plates 2.0 Plates Length 04-16mm* 16-20mm** 04-16mm* 16-20mm** 06, 10mm 04-16mm* 16-20mm** 06-12mm* 14-20mm** 06, 10mm 06-12mm* 14-20mm** Drill 1.0mm 1.2mm 1.6mm Guide GUIDE-1.0/1.2 GUIDE-1.6/2.0 GUIDEMC-1.6 GUIDEMCV-1.6 * 1mm increments available ** 2mm increments

Locking plates for fixation of extra-articular fractures

Our series included 15 patients, with an average age of 35 years, operated on for an extra-articular fracture of the first metacarpal base. All patients underwent surgery with variable angle locking mini-plates. In 10 patients, we used a double-row plate and for the other five patients T-shaped plates. Fractures were immobilized for two weeks. MANUAL OF ORTHOPEDICS - DIYTrade2.0mm MINI PLATE (METACARPAL) FAST LOCKING PLATE HEADLESS HOLLOW COMPRESSION SCREW 11.103.02 Straight Metacarpal Plate - Metacarpal fracture 11.103.04 T-metacarpal Plate - Metacarpal fracture 11.103.06 T-metacarpal Plate - Metacarpal fracture 11.107.31 FAST Mini Locking Plate (High-strength) - Fresh fracture of the non-weight-bearing bone 11

Manufacturer of Mini L- Plates (Left & Right) & Mini T

Mini T- Plates. Get Latest Price. Thickness :1.0mm. Width :5.0mm. Hole Spacing :6.0mm. Fixation with 2.0mm Screws. No. of Holes :02. Code :105.002. View Complete Details. Manufacturer of Mini L- Plates (Left & Right) & Mini T Thickness :1.0mm Width :5.0mm Hole Spacing :6.0mm Fixation with 2.0mm Screws No. of Holes :02 Code :104.L02 104.R02

Midface 1.5mm/2.0mm ium System - Zimmer Biomet

Self-drilling, high-torque screws maximize convenience by reducing the time required for screw placement. 1.5 and 2.0mm self-drilling screws vary in length from 3.5mm to 19mm The Midface 2.0mm ium system plates are available in the standard mini-plate 1.0mm profile and 0.6mm low profile materials to accommodate each surgeon's preferences Midface 1.5mm/2.0mm ium System - Zimmer BiometSelf-drilling, high-torque screws maximize convenience by reducing the time required for screw placement. 1.5 and 2.0mm self-drilling screws vary in length from 3.5mm to 19mm The Midface 2.0mm ium system plates are available in the standard mini-plate 1.0mm profile and 0.6mm low profile materials to accommodate each surgeon's preferences

Mini Plate - 2.0 - 16 Holes Straight 0.6MM KLS Martin

Find many great new & used options and get the best deals for Mini Plate - 2.0 - 16 Holes Straight 0.6MM KLS Martin Germany Pk/1 at the best online prices at ! Free shipping for many products! Mini Plate 4 holes STRAIG W/INT Space T=1.0MM - KLS Martin Germany Pk/1. $30.29. $33.65. Free shipping . Pk/5 Micro Plate - 1.0 - 6 holes Y shape Mini Plates - Changzhou Waston Medical Appliance Co., Ltd China Mini Plates catalog of Surgical Instrument 2.0mm ium Double Oblique L- Cranio - Maxillo - Facial Plate, 2.0mm ium Oblique L- Cranio - Maxillo - Facial Plate provided by China manufacturer - Changzhou Waston Medical Appliance Co., Ltd., page1.

Mini-plate versus Kirschner wire internal fixation for

Apr 11, 2014 · 1. J Orthop Surg Res. 2014 Apr 11;9:24. doi:10.1186/1749-799X-9-24. Mini-plate versus Kirschner wire internal fixation for treatment of metacarpal and phalangeal fractures in Chinese Han population:a meta-analysis. Xu J, Zhang C(1). Pancarpal Arthrodesis Plates Animal Health1 Wagner M. General principles for clinical use of the LCP. Injury, Int. J. Care Injured. 2003;34:S-B31-42. 2 Comparing Pancarpal Arthrodesis Plates vs. LC-DCP Plates

RETRACTED ARTICLE:Mini-plate versus Kirschner wire

Apr 11, 2014 · Inclusion criteria were as follows:(1) the study was designed as randomized controlled trials or retrospective case-control study; (2) the study compared the effect of mini-plate fixation with K-wire fixation for the treatment of metacarpal and phalangeal fractures; (3) patients were adults (18 years old); (4) the outcomes contained at Skeletal Dynamics - Enhancing lives through innovationSkeletal Dynamics LLC 8905 SW 87th Avenue Suite 201 Miami, Florida 33176:Toll-free:Direct:Fax:877.753.5396 305.596.7585 305.596.7591

Surgical Instruments Customization WASTON Medical

1.2mm Mini Hand Plate. Product Information. Product Name:Product No. Holes:Straight plate:10353-104:4:10353-106:6:L- plate:10353-306:6 L:10353-316:6 R:T- plate:10353-206:6:Small T- plate Oblique:10353-406:6 L:10353-416:6 R:Package and Sterilization Treatment The product is supplied in the non-sterile package. After Surgical Instruments Customization WASTON MedicalT Phalange and Metacarpal Plate. L Phalange and Metacarpal Plate. Oblique L-shape Phalange and Metacarpal Plate. W-shape Phalange and Metacarpal Plate. 0.8mm Mini Hand Plate. 1.0mm Mini Hand Plate. 1.2mm Mini Hand Plate. Intramedullary Nail System. Femoral Intramedullary Nail. Reconstruction Femoral Intramedullary Nail.

Surgical Technique - Smith & Nephew

4H, 6H, 8H, 10H, 20H 1.3mm 5.0mm 5mm 101mm 2.4mm plates Geometry Size options Thickness Shaft width Hole spacing Longest plate length T-Plate 2 Hole Head 6H, 8H 1.4mm Shaft:6.0mm, Head:12.3mm 6mm 55mm T-Plate 3 Hole Head 5H, 9H 1.4mm Shaft:6.0mm, Head:18.3mm 6mm 61mm Flex Plate 4H, 6H, 8H, 10H, 20H 1.4mm 6.0mm 6mm 121mm Straight Tine Plate The MetaHUS® fixation system versus pinning and plating in Jun 01, 2014 · The MetaHUS ® technique consists in intermetacarpal percutaneous pinning, then externally connecting the pins by the HK2 ® (Arex) connector (Fig. 1, Fig. 2).Immediate mobilization was allowed ().Download :Download full-size image Fig. 1.Diagram showing the MetaHUS ® fixation technique of a 5th metacarpal neck fracture. Fifth metacarpal neck fracture with palmar angulation (A).

TriLock T-Plate, 5/4 Hole 1.2/1.5 - Medartis

TriLock Rotation Plate, 3/3-Hole 2.0/2.3, 1.2/1.5. Read More. CONTACT. Medartis AG Hochbergerstrasse 60E 4057 Basel/Switzerland. Tel. +41 61 633 34 34 Fax +41 61 633 34 00 Mail [email protected] PRODUCTS. VLP MINI-MOD Small bone Plating System Smith+Nephew VLP MINI-MOD Small Bone Plating System is a modular mini-fragment system designed to treat small bone fractures and small bone fragments. Features. 1.5mm, 2.0mm and 2.4mm Utility Plates and Screws; 3.0mm Osteopenia Screws for patients with poor bone quality; Plates and Screws made of titanium alloy (Ti-6Al-4V)

VLP MINI-MOD Small bone Plating System Smith+Nephew

VLP MINI-MOD Small Bone Plating System is a modular mini-fragment system designed to treat small bone fractures and small bone fragments. Features. 1.5mm, 2.0mm and 2.4mm Utility Plates and Screws; 3.0mm Osteopenia Screws for patients with poor bone quality; Plates and Screws made of titanium alloy (Ti-6Al-4V) metacarpal plates, metacarpal plates Suppliers and CE ISO FDA Mini Fragment Plating System 2.0mm L-Plate Humerus Fracture Metacarpal Bone Plates US $100.00 - $100.00 / Piece

mini plate and screw, mini plate and screw Suppliers and

Mini Plate And Screw 1.5mm 2.0mm 2.5mm 2.9mm Mini Plate And Screw For Finger Metacarpus Made In Zhangjiagang Suzhou . US $10.00-$60.00 / Piece China Manufacturer Orthopedic Implants L Phalange Metacarpal Locking Plates Mini locking plate 6405/6 . US $5.00-$100.00 / Piece mini plate and screw, mini plate and screw Suppliers and Mini Plate And Screw 1.5mm 2.0mm 2.5mm 2.9mm Mini Plate And Screw For Finger Metacarpus Made In Zhangjiagang Suzhou . US $10.00-$60.00 / Piece China Manufacturer Orthopedic Implants L Phalange Metacarpal Locking Plates Mini locking plate 6405/6 . US $5.00-$100.00 / Piece

Hand Plates - Phalangeal & Metacarpal Fracture Treatment

Treat fractures of the phalangeal and metacarpal bones with the Hand Plate system from which features customizable, low-profile locking titanium plates. Learn more at TriMed.

Missing:

  • metacarpal APTUS® Hand - MedartisTriLock T-Plate, 5/4 Hole 1.2/1.5. Hand 1.2 - 2.3. For reconstruction of articular fracture fragments and fractures close to the joint in phalanges. Read More. TriLock Scaphoid Plate 1.2/1.5. Hand 1.2 - 2.3. For nonunions and multifragmentary fractures of the scaphoid.

    Missing:

    Standard plates include the Offset Plate, 6- and 10-Hole Straight Plates, and T-Plates. These plates come in 0.8 mm and 1.3 mm thicknesses, except the Offset Plate which is 0.8 mm only. Plates may be bent to fit and cut to length to better fit individual patient anatomy.

    Missing:

    • metacarpal Hand Plates - TriMed Expose the metacarpal or phalanx with standard techniques. Plates 1.5 Plates 2.0 Plates Length 04-16mm* 16-20mm** 04-16mm* 16-20mm** 06, 10mm 04-16mm* 16-20mm** 06-12mm* 14-20mm** 06, 10mm 06-12mm* 14-20mm** Drill 1.0mm 1.2mm 1.6mm Guide GUIDE-1.0/1.2 GUIDE-1.6/2.0 GUIDEMC-1.6 GUIDEMCV-1.6 * 1mm increments available ** 2mm increments

      Missing:

      Find many great new & used options and get the best deals for Mini Plate 4 holes STRAIG W/INT Space T=1.0MM - KLS Martin Germany Pk/1 at the best online prices at ! Free shipping for many products!

Leave a Comment